Among the many aspects of modern life that we take for granted is the sterilization of materials.
This very important hygienic procedure was developed less than two centuries ago by Louis Pasteur.
Another important step in the history of sterilization was the invention of the autoclave, a laboratory instrument still used today.
Let's find out together.
The father of the autoclave is considered to be Charles Chamberland, a collaborator of the aforementioned Louis Pasteur, who was the first to hypothesize the use of a hermetic sealing mechanism already known for sterilization purposes.
This mechanism is precisely the autoclave which literally indicates a type of hermetic closure in which the difference in pressure between the inside and outside of the container facilitates the seal.
Technically, the pressure cooker we use in the kitchen is also an “autoclave,” but today this term mainly refers to modern moist heat sterilizers that use a seal.
The autoclave is therefore a laboratory instrument consisting of a hermetically sealed environment within which sterilization is carried out by means of saturated steam.
There are other hot air sterilization methods which we have detailed here.
As regards the autoclave, however, the process is divided into three phases.
The autoclave is a commonly used instrument in most laboratories because sterilization is a preparatory procedure for most operations.
In addition to serving as a preparatory step for scientific research, the autoclave is also essential in medical practice for the sterilization of medical devices, such as operating chamber instruments or those found in a dental office.
Finally, sterilization is also required in all non-medical activities that involve the body, such as a tattoo parlor.
Autoclaving practices are described by the international standard EN 13060.
Discover the new series of Environmental Chambers for controlled climate testing.
Find out more.

Saturated steam autoclaving is not the only sterilization method available.
Dry hot air sterilization is an alternative method that meets different needs.
FDM – Environment Makers has been manufacturing laboratory instruments for over 70 years and, when it comes to dry hot air sterilization, we have two different products that perform this function.
On one hand, there are FDM ovens and dryers, specialized in temperature control and capable of reaching extreme values such as 300°.
On the other hand, there are FDM environmental chambers that reach 180° (perfect for the standard procedure) but have many other functions including relative humidity control and can be equipped to carry out most climatic tests.
For any further questions or concerns, please do not hesitate to contact us.
Contact us for more information about this product.
Contact Us
The EN 13060 standard classifies small autoclaves into three classes based on the load they can handle. Class N (Naked) sterilizes only unwrapped solid instruments; typical cycle time 15-20 minutes at 134°C, not suitable for hollow or fabric instruments. Class S (Specified) treats single wrapped and simple hollow instruments as specified by the manufacturer. Class B (Big/Hospital), equivalent to large EN 285 autoclaves, sterilizes any load: porous instruments (fabrics, gauze), hollow (type A lumen cavity), and multiple wrapped instruments. It requires fractionated pre-vacuum (3-4 pulses at −0.9 bar) and daily Bowie-Dick testing according to ISO 11140-4 to verify steam penetration. The standard B cycle: 134°C for 4 minutes or 121°C for 20 minutes.
Saturated steam sterilization requires a temperature-time-humidity combination (100% saturated steam) with a log10 decimal reduction. Standard ISO 17665-1 cycles are: 121 °C for 15-20 minutes (F₀ = 15 min) with a pressure of 1.1 bar; 134 °C for 3-4 minutes (prion 18 minutes according to WHO) with a pressure of 2.1 bar; and 115 °C for 30 minutes for temperature-sensitive products. The Sterility Assurance Level (SAL) 10⁻⁶ requires a reduction of at least 12 logs of the Geobacillus stearothermophilus microbial population (D₁₂₁ = 1.5-3 minutes). The F₀ integrates the equivalent time at 121 °C with a z-value of 10 K and is the reference parameter for cycle validation.
The qualification includes IQ/OQ/PQ. TheIQ verifies installation: PED certificate, class 0.6 pressure gauge calibration, traceability of class A T sensors (PT100 ± 0.15 °C), software documentation ≥ 21 CFR Part 11. TheOQ performs thermal mapping in an empty chamber with 12-30 SIT/ACCREDIA calibrated Type T thermocouples distributed according to EN 285 Annex D, with criteria: band ± 2 °C, equilibrium time ≤ 15 s at 134 °C, saturated steam with NCG < 3.5%. The PQ uses real loads (worst-case load) with thermocouples at the coldest point and biological indicators (BI) Geobacillus stearothermophilus 10⁶ CFU; 3 consecutive cycles with ≥ 6 log reduction. Revalidation annual or after modifications. Cycle parameters must be recorded in real time with an audit trail.
BSL-2/BSL-3/BSL-4 biosafety laboratories require double-door (pass-through) autoclaves for mandatory decontamination of biological waste before disposal. Typical cycle: 121°C for 60 minutes for liquids, 134°C for 20-30 minutes for contaminated solid waste (bottles, pipettes, PPE). Thermally slow loads (5-10 L liquid bottles) require a liquid cycle without initial vacuum with controlled cooling to prevent boil-over, or overpressure (air ballast) with +0.3 bar above saturation. BSL-3 autoclaves must have HEPA ventilation, biotight sealing on the dirty-side door, and 100% traceability of cycle parameters according to the WHO biosafety manual. Prion inactivation requires a 134°C/18-minute cycle with 1N NaOH pretreatment according to Creutzfeldt-Jakob guidelines.