UV chamber • Photodegradation test

UV Light Test Chamber

Accelerated simulation of ultraviolet radiation on materials, surfaces, and packaging. Photodegradation tests with UV-A, UV-B, and UV-C lamps, temperature and humidity control.

ISO 4892ASTM G154ICH Q1B
UV Light Test Chamber

140 – 2300 L

Available volume

−10° / +55°C

Temperature range

10 – 80% rH

Humidity RH

UV-A/B/C

Lamps available

REQUEST A QUOTE

Response within 24 hours.

Fill out the form. A technician will contact you within 24 business hours with a customized proposal for your lab.

Telephone
+39 06 29 80 42

Prefer to write?
Fill out the request form: it will reach our technical office with the product reference you're looking at.

1Test parameters
2Setup & Investment
3Your contacts

Step 1 of 3 · Test parameters

Define the test conditions

Thermal range and humidity management. Please indicate your chamber's operating specifications.

Temperature Range

Selected value: 0 °C
Select the minimum value of the operating range
Selected value: 0 °C
Select the maximum value of the operating range
Active Humidity
Required for corrosion testing, accelerated aging and climate simulation (5–98% RH)

ADVANCED TECHNOLOGY

Controlled UV Simulation

Accelerated photodegradation tests with precise control of radiation, temperature, and humidity. UV-A, UV-B, and UV-C lamps with programmable light/condensation cycles.

MAIN FEATURES

Precision and versatility in every detail.

01

Customizable UV Lamps

UV-A 340nm, UV-B 313nm, UV-C 254nm. Vertical or horizontal arrangement with guaranteed uniformity.

02

Complete Climate Control

Temperature from -10°C to +55°C and humidity 10-80% RH for complete light/condensation cycles.

03

Certified Uniformity

Even distribution of UV radiation across all shelves for repeatable results.

04

Advanced Programming

revoFACE touchscreen controller with 10 programs and 50 segments for complex cycles.

05

Condensation Simulation

Ultrasonic humidification system for alternating UV/humidity cycles according to ISO 4892.

06

Security and Traceability

Intelligent alarms, USB data logging, RS232/Ethernet interfaces for remote monitoring.

TECHNICAL DATA

Full specifications.

IQ/OQ documentation available upon request. Full datasheet in PDF format.

ISO 9001Made in Italy24 month warrantyIQ/OQ available

OPERATIONAL DIAGRAM

Temperature — humidity range

Volume140 – 2300 L
Temperature range−10°C / +55°C
Humidity10 – 80% RH
UV-A340nm lamps (solar aging)
UV-B313nm lamps (accelerated degradation)
UV-C254nm lamps (sterilization)
Vertical or horizontal arrangement
revoFACE color touchscreen controller
Lamp life1000 – 5000 hours
ConnectivityUSB, RS232, Ethernet
ISO 4892, ASTM G154, ICH Q1B compliant

Controller

Two controllers. Two testing philosophies.

Each FDM camera is equipped with the controller best suited to your working method. Both are designed and manufactured in Italy.

stillFACE controller - FDM Environment Makers
Constant monitoring

stillFACE

Two dedicated displays for temperature and humidity. Manual setting, instant readings, zero distractions—the perfect controller for testing under constant conditions.

  • →High visibility LCD display — 2 separate channels
  • →Manual setting of setpoints and parameters
  • →Continuous monitoring under constant conditions
  • →Configurable audio-visual alarms
  • →Optional RS485 interface for data logging
Ideal for Stability Testing · Passive Monitoring
PROGRAMMABLE
revoFACE controller - FDM Environment Makers
Cyclic programming

revoFACE

Color touchscreen with intuitive interface. Program complex cycles with ramps, pauses, and transitions—up to 10 programs with 50 segments each.

  • →7″ color touchscreen with intuitive interface
  • →10 programs × 50 segments — cycles from 1 min to 999 h
  • →Ramps, stasis and programmed transitions
  • →USB data export · event log and setpoints
  • →RS485 · Ethernet · Dedicated mobile app
Ideal for automated cycles · advanced search

CONFIGURATOR

Set up in 1 minute.

Four steps: test parameters, camera configuration, budget and timeline, contact us. Receive a personalized quote within 24 business hours.

01

Test parameters

Temperature range · humidity · illumination

02

Configuration

Volume · accessories · controller

03

Budget & Time

Planned investment · project start-up

04

Contact

Proposal within 24 working hours

Frequently Asked Questions

FAQ.

Can't find your answer? Talk to an expert →

UV-A lamps (340nm) simulate sunlight, which causes long-term aging. UV-B lamps (313nm) are more aggressive and further accelerate degradation. UV-C lamps (254nm) are used for sterilization tests and specific applications. The choice depends on the type of test and the relevant regulation.
Accelerated UV tests can simulate months or years of natural exposure in just a few days or weeks. The acceleration factor depends on the radiation intensity, the cycle selected, and the material tested. Typically, a correlation of 1 week of testing = 3-12 months of actual exposure is obtained.
Yes, thanks to the adjustable shelves, you can simultaneously test different samples of materials, products, or packages. The uniformity of the radiation ensures that all samples receive the same UV exposure for comparable results.
Yes, our UV chambers can be configured to comply with various regulations: ISO 4892 (plastic exposure), ASTM G154 (cyclic weathering), ICH Q1B (pharmaceutical testing), and other industry-specific standards. We can customize the chamber to meet your applicable regulations.
UV lamps typically last 1,000-5,000 hours, depending on the type. We recommend monitoring the radiation intensity and replacing the lamps when they reach approximately 80% of their useful life to maintain accurate results. Replacement is simple and does not require specialized technical assistance.
Absolutely. The Advanced configuration allows you to program complex cycles that alternate between UV radiation, heating, cooling, and condensation. This realistically simulates real-world environmental conditions such as day/night cycles or seasonal variations.
It depends on the volume you choose. The 140-liter chambers are compact and suitable for laboratories with limited space, while models up to 2300 liters require larger spaces. Generally, allow at least 50 cm of free space on all sides for ventilation and maintenance.
Yes, we specialize in customization. We can configure UV lamp types, intensity, layout, pre-programmed cycles, specific interfaces, and any other requirements for your testing protocols. Contact us to discuss your specific needs.
RELATED PRODUCTS

Find the perfect solution.

Xenon Light Test Chamber
XENON LIGHT TEST CHAMBER

Xenon Light Test Chamber

ICH Q1A/B Test Chamber
ICH Q1A/B TEST CHAMBER

ICH Q1A/B Test Chamber

Chambers with Lighting
CHAMBERS WITH LIGHTING

Chambers with Lighting

START NOW

Ready to find the perfect UV light test chamber?

Guided setup, 24-hour quote, dedicated technical support.