Climatic Chamber Configurator
Discover the Climatic Chamber Configurator
Our guide to choosing the climate chamber best suited to your needs.


A laboratory thermostatic bath is an instrument used to heat and maintain samples of substances, solutions, or components at a controlled temperature. It consists of a stainless steel tank filled with a heat transfer fluid—water or oil—which ensures uniform heat distribution.
Unlike hotplates or ovens, a thermostatic bath provides indirect and uniform heating, without hot spots or thermal gradients. This makes it indispensable in all processes where thermal precision is critical: from sample preparation to instrument calibration to regulatory compliance testing.
The operating principle is simple but effective. An electric heating element heats the fluid to the set temperature, while a temperature sensor (usually a Pt100 probe or thermistor) provides continuous feedback to the controller. The PID regulation system maintains a stable temperature with typical tolerances of ±0.1°C.
FDM thermostatic baths are equipped with electro-welded tanks in AISI 304 or AISI 316 stainless steel and an external control interface — digital or analogue — that allows you to program thermal cycles and automate processes.
The key elements of a thermostatic bath are:
The choice of heat transfer fluid determines the temperature range and possible applications. There are two main categories of thermostatic baths:
The thermostatic water bath is the most common model in laboratories. It uses distilled or deionized water as the fluid and reaches temperatures up to 100°C (99.9°C to be precise, avoiding boiling). It is the ideal choice for:
The main advantage is the low cost of the fluid and ease of maintenance. The disadvantage is the temperature limit of 100°C.
The oil thermostatic bath uses silicone oil as a heat transfer fluid and reaches temperatures up to 200°C. As an alternative to silicone oil, mineral oil or other high-boiling fluids can be used.
Typical applications include:
The oil bath requires greater attention in maintenance and management of the used fluid, but it is irreplaceable for all applications above 100 °C.
The thermostatic bath is used in numerous industrial and research sectors:
The choice of model depends on four main factors:
For those who need complete climate control (temperature + humidity), it is possible to evaluate a climatic chamber, which offers a closed environment with programmable parameters.
FDM Environment Makers has been designing and manufacturing thermostatic laboratory baths since 1949, entirely in Italy. Our models offer AISI 304 or 316 stainless steel tanks, capacities up to 360 liters, and an intuitive control interface for programming automated heating cycles.
Each FDM thermostatic bath can be configured to meet your lab's specific needs: volume, fluid, temperature range, and accessories. For special needs, we also create custom solutions.
Discover FDM Thermostatic Baths or contact us for technical advice.
The choice of heat transfer fluid depends on the operating range and application.Deionized water covers 5-95°C, has excellent heat capacity (4.18 kJ/kg K), is inexpensive, but has limitations: below 0°C it freezes, above 100°C it evaporates, and promotes corrosion of metal components. The addition of ethylene glycol (30-50%) extends the range to -25/+100°C but reduces thermal conductivity and requires biocides.Silicone oil (typically polydimethylsiloxane) covers -80/+300°C with high oxidative stability, controlled viscosity, and compatibility with most materials. Limitations: high cost (50-200 EUR/L), lower heat capacity (about 1.5 kJ/kg K), and periodic maintenance due to degradation above 200°C with gel formation. For SIT/ACCREDIA metrological calibrations, dedicated oils (Fluorinert FC-77, Dow Corning 510) with low viscosity and non-toxicity are used. For GMP pharmaceutical applications, USP purified water with continuous circulation and 0.22 μm filtration is preferred.
The performance of professional thermostatic baths is characterized by three DIN 12876 parameters: temporal stability (fluctuation at the set point, typically +/- 0.01 / +/- 0.05 C), spatial uniformity (gradient in the useful volume, 0.02 – 0.5 C), setting precision (deviation between set point and mean value, 0.1 – 0.5 C). A generic laboratory bath has stability 0.05 C at 37 C, uniformity 0.2 C in 10 L. A metrological calibration bath achieves 0.005 C stability and 0.01 C uniformity through forced fan agitation, a distributed heating circuit, and a reference PRT sensor. The IQ/OQ/PQ qualification requires 9-point mapping with ACCREDIA-calibrated Pt100 Class 1/10 DIN probes, test duration 1 hour after stabilization, and full SI traceability. Calibration must be repeated annually or after each intervention on sensors/controls.
The calibration of secondary thermometers (thermocouples, industrial PRTs) is carried out by comparison in a thermostatic bath with a reference thermometer SPRT or PRT Class 1/10 calibrated by SIT with ITS-90 traceability. Procedure: (1) immersion of sensors at a depth >= 10x diameter to eliminate stem conduction; (2) stabilization 15-30 min at the setpoint; (3) simultaneous reading of reference and device under calibration, at least 10 readings at 30 s intervals; (4) calculation of mean, standard deviation, deviation from the reference; (5) repetition at 3-5 setpoints covering the range; (6) calculation of extended uncertainty U95 according to GUM including contributions from the bath (uniformity, stability), reference, DUT, drift over time. The calibration certificate compliant with ISO/IEC 17025 must include the metrological chain, coverage factors k=2, reading table, recalibration interval recommendations (typically 12 months).
DIN 12876 classifies thermostatic baths into 3 safety classes according to the fluid: Class I for non-combustible liquids (water); Class II for combustible liquids with T flash > T setpoint + 25 C; Class III for combustible liquids with T flash close to the setpoint (more stringent). Specific risks for silicone oils at T > 150 C include: (1) thermal degradation with release of flammable vapours (formaldehyde, volatile siloxanes); (2) accumulation of humidity with formation of bubbles and thermal overshoot; (3) rupture of coils due to thermal shock. Mandatory safety systems include: independent safety thermostat with manual reset (typical limit +10 C above setpoint), fluid level sensor with cut-off, overheating protection due to empty tank, expansion valve for thermal expansion, ventilated casing for vapour dispersion. Installation in a fume hood is recommended for T > 200 C with oils.
Do you need to pass a regulatory test or are you looking for a chamber designed to your test protocol? Tell us your needs: the FDM technical team will respond to you, without intermediaries.