Have you experienced a breakdown with your environmental chamber and are looking for environmental chamber repair services?
Or do you want to know in advance what environmental chamber repair so you can be prepared for any eventuality?
In the following article we will try to resolve all your doubts on this matter, first addressing the topic of environmental chamber repair in general and then the repair services of our climatic chambers FDM – Environment Makers.
The first question that comes to mind is how often you need to repair your environmental chamber yourself or turn to specialized environmental chamber repair services
The answer is: very little.
The reason is simple: climatic chambers are highly sophisticated instruments, built to last.
Since it's a rather expensive investment, it's in the best interest of both the manufacturer and the customer that the final product meets expectations. For this reason, almost every climate chamber manufacturer performs an initial calibration of the chamber during the testing phase and then provides the customer with the relevant certification.
It is therefore not common to have to deal with failures in the ordinary use of environmental chambers and climatic chambers.
However, if the instrument is used frequently for long periods of time, wear and tear –perhaps coupled with incorrect routine maintenance– may cause some problems.
Let's see which ones.
Discover the new series of Environmental Chambers for controlled climate testing.
Find out more.

An important distinction to make when discussing interventions on the climatic chamber is between ordinary and extraordinary maintenance.
By routine maintenance, we mean a whole series of interventions and routine checks that are necessary for the correct functioning of the environmental chamber, to keep its performance always above certain standards and avoid actual failures.
It involves periodically checking the functioning of all systems, carefully cleaning certain components and replacing others with a certain frequency.
We've covered this topic in detail here.
Extraordinary maintenance, on the other hand, refers to actual breakdowns and malfunctions that often require the intervention of a technician.
Of all the components in an environmental chamber, those that are most frequently subjected to stress are the most subject to failures that partially or completely compromise its functioning.
These include: the refrigerator compressor, the water loading valve, the various fans, the temperature and humidity probe, the humidification system, and even the so-called "brains" that control the entire climate testing system.
These are very delicate components whose repair requires specific knowledge that only specialized technicians can provide. If you have the right technicians at your company, you can repair the climate chamber yourself.
However, we recommend contacting the manufacturer directly , who should guarantee a technical assistance service capable of carrying out prompt repairs.
This is how we do it at FDM – Environment Makers.
Send us a request and discover our Calibration offer.
Find out more.

For over 70 years, we have been building environmental chambers with professionalism and passion, always focusing on our customers' needs. For this reason, FDM – Environment Makers offers an environmental chamber repair service through our prompt technical support team , available at support@dellamarca.it.
Additionally, our engineers can remotely connect to the camera via the RS485 port (stillFACE) or Ethernet interface (revoFACE) to make an initial assessment of the nature of the problem.
If you need anything, please do not hesitate to contact us.
Contact us for more information about this product.
Contact Us
The most frequent failures in statistical order: (1) PT100/capacitive RH (30-40% of cases) causes out-of-spec uniformity; (2) sensor drift refrigerant leak (15-20%) with loss of cooling capacity and low pressure alarms; (3) resistance humidifier failure with limescale or corrosion; (4) compressor (stage low R23/R508B in particular, MTBF 20,000-30,000 hours); (5) solenoid valves stuck on cascade cycle; (6) internal bearing fans ; (7) PLC/HMI controller with data loss or freeze. Diagnostics require: recording temperature/RH/pressure trends, visual inspection with IR thermography, refrigerant leak check with electronic gas detector (sensitivity 3-5 g/year), checking working pressure gauges (high 10-25 bar, low -0.5 to +3 bar depending on refrigerant).
Regulation 517/2014 requires for all interventions involving fluorinated gases (R404A, R448A, R23, R508B, R134a): a technician with an F-Gas category I or II license (Presidential Decree 146/2018 in Italy), registration of the intervention in the Ministry of the Environment Database, and use of a certified recovery station with efficiency ≥ 95%. Mandatory leak checks: annually for systems 5-50 t CO₂eq, semi-annually for 50-500 t, quarterly for > 500 t. Traditional HFC refrigerants (R404A GWP 3922) are being phased out: from 2025, a ban on new commercial systems. Natural refrigerants (R290 propane, R744 CO₂, R717 NH₃) require specific licenses and safety evaluations (ATEX for propane). The technical invoice must indicate the refrigerant type, kg loaded/recovered, and post-intervention tightness check with bubbles or electronic detector.
Major interventions (compressor replacement, complete refrigerant recharge, sensor replacement, humidifier repair, PLC firmware update) require complete requalification according to IEC 60068-3-5/6. Protocol: (1) sensor recalibration with ACCREDIA traceable references (PT100 uncertainty ≤ 0.15 °C, RH ≤ 1.5%); (2) thermal mapping of 9-27 points of the useful volume for at least 24 hours including operating setpoints (typically -40, +23, +85 °C); (3) spatial gradient verification (target ≤ 2 °C) and temporal fluctuation (≤ 0.5 °C); (4) recovery test after 30 s door opening; (5) alarm verification . IQ/OQ/PQ documentation updated with 21 CFR Part 11 audit trail. Minor interventions (filters, gaskets) require only spot verification with reference instrument.
The economic rule is the 50% rule: if the repair cost exceeds 50-60% of the value of a new equivalent chamber, it is worth replacing. Additional factors to consider: (1) machine age (> 12-15 years the probability of chained failures increases); (2) component obsolescence (phase-down prohibited refrigerants, PLCs no longer supported); (3) energy efficiency (new chambers with inverters and natural refrigerants consume 30-50% less according to Ecodesign Reg. EU 2019/2019); (4) regulatory compliance (new CE, EMC, cybersecurity IEC 62443 regulations). The 10-year TCO includes: purchase cost, electricity (kWh/year × €/kWh), scheduled maintenance (3-8% value/year), annual recalibrations (1,500-5,000 €/each), periodic F-Gas recharging (500-2,000 €/each). A complete revamp at 40-60% of the cost of a new one with a 24-month warranty can extend its useful life by 5-8 years.
Do you need to pass a regulatory test or are you looking for a chamber designed to your test protocol? Tell us your needs: the FDM technical team will respond to you, without intermediaries.