Laboratory freezer for low-temperature sample storage

Laboratory Freezer: A Guide to Choosing for Temperatures Down to -40°C

A laboratory freezer is an essential tool for the low-temperature storage of biological samples, chemical reagents, and sensitive materials. Unlike home freezers, laboratory models offer extended temperature ranges (down to -40°C or lower), superior thermal stability, and alarm systems to protect samples in the event of abnormalities.

In this guide we will examine the different types of laboratory freezers and refrigerators, their applications by sector and the criteria for choosing the right model.

Types of Laboratory Freezers

Laboratory freezers are divided into three main categories based on the temperature range they can reach:

Standard Refrigerators and Freezers

They operate in a range from +2°C to -40°C. They are the most common models in laboratories and are used for the daily storage of reagents, samples, and solutions that require controlled but not extreme temperatures. FDM refrigerators and freezers fall into this category, with ranges from -40°C to +15°C and customizable volumes.

Ultra Freezers

They reach temperatures as low as -86°C/-90°C. They are essential for the long-term preservation of critical biological samples: vaccines, enzymes, tissue samples, and genetic material. The technology uses dual cascade compressor systems to reach and maintain such low temperatures with stability. For more information, read our article on how ultra-low freezers work.

Cryogenic Freezers

They use liquid nitrogen as a coolant and reach temperatures below -150°C (down to -196°C). Liquid nitrogen surrounds the sample, ensuring rapid and uniform cooling. They are used for the cryopreservation of stem cells, DNA samples, embryos, and biological tissues intended for advanced medical research.

Applications by Sector

Laboratory freezers are used in numerous sectors:

  • Pharmaceutical and medical: vaccine storage according to WHO cold chain guidelines , storage of diagnostic reagents, storage of biological samples for clinical trials
  • Scientific research: long-term preservation of cell cultures, biobanks, DNA/RNA samples, tissue cryopreservation
  • Agri-food: microbiological analysis of food samples, conservation of reference bacterial strains, low-temperature shelf-life testing
  • Chemical and cosmetic: storage of temperature-sensitive reagents, preservation of samples for stability tests
  • Energy and Batteries: Low-temperature cell and battery performance testing, simulating winter operating conditions

How to Choose the Right Laboratory Freezer

The choice of model depends on five main factors:

  • Temperature range: up to -40°C → standard freezer. Up to -90°C → ultra-low freezer. Below -150°C → liquid nitrogen cryogenic
  • Internal volume: to be evaluated based on the number and size of samples. FDM offers customizable volumes for every need.
  • Thermal stability: for critical samples (vaccines, stem cells) check the declared tolerance and the presence of alarm systems
  • Energy efficiency: Laboratory freezers operate 24/7 — energy consumption significantly impacts operating costs
  • Regulatory Compliance: For pharmaceutical and clinical applications, verify GMP compliance and availability of IQ/OQ/PQ documentation

For those who also need complete climatic tests (temperature + humidity + programmable cycles), it is possible to evaluate a climatic chamber with an extended range towards low temperatures.

The FDM Solution

FDM Environment Makers has been designing and manufacturing laboratory refrigerators and freezers since 1949, entirely in Italy. Our models cover a range from -40°C to +15°C with customizable volumes and precise control systems.

Each FDM freezer can be configured with specific accessories: multiple temperature probes, alarm systems, continuous data recording, and IQ/OQ qualification documentation. For specific needs, we also create customized solutions.

Discover FDM Refrigerators and Freezers or contact us for technical advice.

Reference Standards

  • IEC 61010-2-011 — Safety requirements for measurement, control and laboratory equipment, Part 2-011 applicable to laboratory refrigeration appliances.
  • NF X 15-140 — French international reference standard for the performance qualification of medical freezers and thermostatic chambers.
  • EN 12830 — Temperature recorders for the transport, storage and distribution of chilled, frozen and quick-frozen foods.
  • ISO/IEC 17025 — General requirements for the competence of testing and calibration laboratories, applicable to freezers used as accredited instruments.
  • DIN 58345 — Medical refrigerators: specific requirements, classification and test methods for the storage of biological samples and drugs.
  • GDP EU 2013/C 343/01 — European guidelines on Good Distribution Practices for the pharmaceutical cold chain.

Authoritative Sources

Frequently Asked Questions about the -40 C Laboratory Freezer

What is the practical difference between -20, -40 and -80 C?

The choice of temperature depends on the biochemical stability of the samples. At -20°C , generic reagents, antibodies diluted in glycerol, and diagnostic kits can be stored for 3-12 months, but residual enzymatic reactions are still measurable. At -40°C, molecular mobility is drastically reduced: genomic DNA, plasmids, sera, and vector vaccines can be stored stably for 2-5 years. At -80°C , the threshold below the glass transition temperature of intracellular water (-132°C) is only partially reached, but sufficient for cells, RNA, labile proteins, and biobanks for 10+ years. -40°C represents the best cost/benefit compromise for clinical laboratories and research centers: energy consumption 40-60% lower than -80°C, heat load manageable with a single cascade compressor, and a smaller footprint. The choice must be validated against the sample's documented stability in the reagent manufacturer's specifications or in the reference pharmacopoeia.

How does a -40C freezer qualify for GMP use?

The qualification follows the IQ/OQ/PQ referred to in the GMP Annex 15 and GDP EU 2013/C 343/01 guidelines. Installation Qualification (IQ): verification of dedicated power supply, UPS backup, maintenance access, traceability of critical components. Operational Qualification (OQ): stability test at setpoint in an empty chamber according to NF X 15-140, ramp-down, recovery time after door opening of 60 s, high/low temperature alarms, power failure resistance test (recovery within 4 h with the door closed). Performance Qualification (PQ): thermal mapping at typical load in 9-15 points with ACCREDIA certified calibrated dataloggers, measurement uncertainty

Can the defrost cycle compromise the samples?

Professional -40 C freezers adopt manual defrost or localized hot gas auto-defrost. The traditional automatic defrost with resistors (typical of domestic ones) causes excursions of +5 / +10 C at 6-12 h intervals, unacceptable for biological samples. Laboratory models use: (1) oversized evaporators with low frost formation; (2) hot gas defrost injected only into the coil, with thermal insulation of the useful volume; (3) door with heated perimeter anti-condensation gasket. The correct procedure involves manual defrost every 6-12 months by emptying the volume, with internal temperature monitoring to document excursions. Some models integrate LN2 backup that maintain -30 C during defrost for critical samples.

Which parameters should be continuously monitored?

Minimum requirements for GDP/GMP compliance include: (1) useful volume temperature with annually calibrated Pt100 Class A probe ( multi-threshold alarm (pre-warning -35 C, critical -30 C) with SMS/email notification; (3) local ambient temperature (typical limit 15-32 C for nominal operation); (4) compressor absorption for early failure detection; (5) number and duration of door openings via reed contact; (6) power failure events with duration. Recording must have a frequency >= 1 point/minute, local (SD card) and cloud redundancy, minimum retention 5 years for regulated sectors. The audit trail must track every change of setpoint or alarm threshold with authenticated user and timestamp.

Speak directly with our engineers

Do you need to pass a regulatory test or are you looking for a chamber designed to your test protocol? Tell us your needs: the FDM technical team will respond to you, without intermediaries.

1What do you need?
2Your project
3How we contact you
Step 1 of 3

What do you need?

Please indicate the type of request so that we can direct it to the most appropriate specialist.